| Socket Adapter (click to buy) | Description | Package | Devices Supported | Adapter Capacity per Site | Sockets per Adapter | 2900L, 3910, 4910, 3928, 3901, 3900, 2900, 4900, 1900 | 3800, 3000FS-MK2, 3000FS, 2800F-MK2, 2800F, 2800, 4800 |
|---|---|---|---|---|---|---|---|
| FVE4ASM24BGB | Automated SOCKET CARD, 24 PIN BGA | TFBGA(24) | 840 | 2, 3 or 4 | 1 | ✓ | ✓ |
| Device Name | Winbond W25M512JVBIQ (ID=18h) |
| Manufacturer | Winbond |
| Part Number | W25M512JVBIQ (ID=18h) |
| 8-bit Bytes | 67121408.0 |
| Vcc(program) | 3.6 |
| Set programming | Yes |
| Memory Regions | 0h-1FF FFFFh; 200 0000h-3FF FFFFh; 400 0000h-400 00FFh; 400 1000h-400 10FFh; 400 2000h-400 20FFh; 400 3000h-400 30FFh; |
| Electrical Erase | Yes |
| Packages | TFBGA(24) |
| Notes | IMPORTANT: 512M-bit Serial Flash. This algorithm uses Standard SPI mode to Program and Verify/Read the device. The status register bits can be set under Device > Configure . There are four 256-Byte Security Registers with OTP locks independent from main memory mapped to [4000000-40000FF][4001000-40010FF][4002000-40020FF][4003000-40030FF] in the Data Pattern respectively. Please note that Security Register 0 (mapped to [4000000-40000FF]) is reserved by Winbond for future use. It is recommended to use Security registers 1-3 before using register0. The default Device Range is set to [0000000h-3FFFFFFh]. Please modify the range under Device > Range if any of the Security Registers needs to be included. |
| Programmer | 3900 |
| Socket Modules | FVE4ASM24BGB |
| Device Name with Package | Winbond W25M512JVBIQ (ID=18h) TFBGA(24) |
| Device Name with Package and Adapter | Winbond W25M512JVBIQ (ID=18h) TFBGA(24) FVE4ASM24BGB |