Device Name | International Rectifier IR38060MTRPBF |
Manufacturer | International Rectifier |
Part Number | IR38060MTRPBF |
8-bit Bytes | 1536.0 |
Vcc(program) | 3.3 |
Set programming | Yes |
Memory Regions | 0h-5FFh; |
Electrical Erase | nan |
Packages | LAP(26) |
Notes | IMPORTANT: Single Output Digital Multi-Phase Controller. The on-chip Multiple-Time Programmable (MPT) memory is located in at device address 20h -72h (BPWin buffer address 0h-F0h). Registers 6Eh 6Fh 71h and 72h will remain at factory setting and will not be programmed or verified. There is a limit on the maximum number of reprogramming attempts. If this limit is exceeded programming operation will fail. Please refer to device specifications for details. The Compare function is disabled. Please use the Read function in lieu of Compare to verify the programmed User data. After performing a Read the User data will be located in the buffer at 20h-70h. Ignore all data found at buffer locations 0h-1Fh 6Eh 6Fh and 71h-FFh. The data file (TXT) requires a specific format for programming this device. This configuration file contains 134 lines of space delimited text formatted into three columns of text. Refer to IR’s Technical Brief for additional information. When loading the TXT data file into the buffer please verify that BPWin indicates the format is Straight The data pattern must contain FFh after the last valid data address other wise it will fail programming and verify due to the data pattern being incorrect.The data pattern must not contain the trim data otherwise it will fail programming and verify due to the data pattern being incorrect. Read has been setup to mimic the 3-column data pattern format but will set a default mask of 0xFF. Therefore operator cannot recreate master design file from a programmed device. Read has been setup to mimic the 3-column data pattern format but will set a default mask of 0xFF. Therefore operator cannot recreate master design file from a programmed device. " |
Programmer | 3900 |
Socket Modules | FVE4ASML26QFNA |
Device Name with Package | International Rectifier IR38060MTRPBF LAP(26) |
Device Name with Package and Adapter | International Rectifier IR38060MTRPBF LAP(26) FVE4ASML26QFNA |